| Series 5 - High-Voltage AC-Motors - Siemens | 12/05/2008 0:04 PM | ||
Hide Images |
Print
|
As a result of their modular design, the 1R.5 slipring rotor motors (US: wound-rotor motors) can be produced with various cooling systems. This means that the motors can be flexibly adapted to the customers's application.
The enclosed slipring compartment – located inside the NDE bearings – guarantees a high degree of protection for the complete motor, i.e. for the motor and slipring compartment.
| Features | Customer benefits |
| Compact design as a result of a high power density and inboard slip ring compartment |
|
| Modular cooling system design | Can be integrated into every plant and system configuration |
| Low noise | High demands of safety at work legislation are fulfilled |
|
Terminal box mounted to the motor enclosure The cover is de-coupled from the electrical connections |
Service and installation friendly |
| Motors are either available in a version where the brushes are permanently in contact with the sliprings or a version with brush lifting device | Brush operating mode can be optimally adapted to the process conditions |
| Brief overview | |
| Motor type: | Slipring rotor |
| Water-cooled motors: | 1RU5 type series |
| Air-cooled motors: | 1RR5 type series |
| Shaft heights: | 400, 450, 500, 560, 630, 710, 800, 900 mm |
| Power range: | 0.3 to 8 MW |
| Rated voltages: | 3.3 - 11 kV |
| Degree of protection: | IP55 |
| Cooling type: | IC 611, IC 81 W, IC 01 |
| Type of construction: | IM B3 (IM 1001) |
| Bearings: | Roller bearings (up to SH 710), sleeve bearings (from SH 800) |
| Regulations/Standards: | IEC, EN |